Dreusicke offers the fine tools you will need for the maintenance and repair of office machines, computers, electronic and/or fine-mechanical devices. (for commercial users only)
Scaled discount on catalog price: from 12 pcs. 5%, from 48 pcs. 10% and from 96 pcs. 20%!
Unique pressure-sensitive tackifier. Special open structure for excellent dust pick up. Ideal for cleaning of furniture, computers, tables and desks. Leaves no surfaces residue. Low-lint. Quaranteed silicon free. Suitable for painting and spraying applications. High degree of user convenience.
Dimensions: 43 x 37 cm
Colour: yellow
Fibre compositions: 50% polyester, 50% viscose and 20% binding agent
Contens: 25 wipes
Applications:
Electronic and computer industries, pharmaceuticals and health care environments.
Part list
mobile - network-independent testing due to battery operation
easy - operation by means of push-buttons
quick - testing within a few seconds
all-in-one - protective conductor current measurement by means of differential current or alternative leakage current measurement method
Testing of devices with mains voltage-dependent switching elements/ mains supply units/ relays such as controlled devices/tools, devices of information and communication technology as well as of devices which can be tested completely with mains voltage only.
In mains operating mode, the protective conductor current/ contact current is measured by means of the required differential current/direct measurement method.
New product features
- storage locations for 999 test samples
- 3 hot keys for storing, calling and printing the measured values
- mini-USB interface and download software for the preparation of test certificates in MS Excel
- direct printing function for printing test certificates on site by means of optional printer BENNING PT 1
- prolonged functional test and differential current measurement (max. 2 x 5 minutes)
- integrated real-time clock for storing the measured values including the test date
Features
- automatic testing procedure for devices of class I (key 1), class II/III (key 2) and line test (key 1)
- testing of cable reels, multiple distributors and device connecting cables with IEC connector
- measuring result with "PASS / FAIL" indication
- limiting values preset
- mains operating mode for tests under operating conditions
- battery operating mode for mobile testing
- reduction of the ISO testing voltage for devices with overvoltage arresters
- indication of correct function key in case of incorrect operation, overload and if the test sample is not switched on
- sufficient battery capacity for more than 2,500 test samples
Measuring functions
- protective conductor resistance with a pulsed testing current of 200 mA (required in case of oxidized contacts
- insulating resistance with a testing voltage of 250 V and 500 V
- mains operating mode: protective conductor current/contact current by means of differential current/direct measurement method with automatic mains pole reversal
- battery operating mode: protective conductor current/contact current by means of alternative leakage current measurement method
- active testing of three-phase devices under operating conditions by means of optional measuring adapters
- testing of permanently installed and portable 30 mA RCDs/PRCDs with tripping time measurement
- voltage measurement on external shock-proof
Scope of delivery:
carrying case, test cable with alligator clip, mains connection cable, appliance cable, download software (CD), USB cable, battery set